FEATURES
SUPPLIED WITH
Input cable | 16 2-meter STYV-2 cables fitting with BNC socket at one end and L2 plug at other end. |
Output cable | 16 2-meter coax cable with BNC sockets |
Power supply cable | AC power supply cable (0.3A) |
PERFORMANCE
Input channels | 16 |
Input voltage range | -10V to 10v peak (ICP transducers output) |
Supply voltage to transducer | 24V DC |
Supply current to transducer | 4mA or 10mA (default to 10mA) |
Output voltage | -10V to +10V peak |
Output current | 5mA |
Gains | ×1, ×10 |
Accuracy | =±1.0% |
DC offset | ±10mV |
Noise | =1mV |
Upper cutoff frequency | 100kHz, |
Lower cutoff frequency | 0.3Hz |
Power supplies | AC 220V±10%,at 50Hz and 0.2A, DC 20 to 36 V/100mAV (recommend 24V) |
PHYSICAL CHARACTERISTICS
Dimensions | 430mm(W) × 44mm(H) × 240mm(D) |
Weight | 2kg |
Electrical connection | BNC plugs for input; BNC plugs and 25 way D socket for output |
ENVIRIONMENT CHARACTERISTICS
Operating temperature | 0°C to 40°C |
Storage temperature | -55°C to 85°C |
Maximum humidity | 95% RH |